Cleared Special

K203199 - RAS 12 Rack / RAS 12 Long Rack, used in RAS Cycle of AMSCO 7052HP / 7053HP Single Chamber Washer-Disinfector (FDA 510(k) Clearance)

Dec 2020
Decision
33d
Days
Class 2
Risk

K203199 is an FDA 510(k) clearance for the RAS 12 Rack / RAS 12 Long Rack, used in RAS Cycle of AMSCO 7052HP / 7053HP Single Chamber Washer-Disinfector. This device is classified as a Washer, Cleaner, Automated, Endoscope (Class II - Special Controls, product code NVE).

Submitted by STERIS Corporation (Mentor, US). The FDA issued a Cleared decision on December 1, 2020, 33 days after receiving the submission on October 29, 2020.

This device falls under the General Hospital FDA review panel. Regulated under 21 CFR 876.1500. This Automated Device Is Intended To Be Used To Clean Endoscopes. Endoscopes That Are Intended To Be Cleaned By The Automated Cleaner System Should Have Been Pre-cleaned And Tested For Leaks And Lumen Obstructions According To The Instrument Manufacturer's Instructions And Current Professional Practices Prior To Processing In The System. The System Includes A Chemical Dispensing System That Meters Out A Predetermined Volume Of Detergent During The Appropriate Cleaning Cycle. If The Device Is Reusable, Validated Reprocessing Instructions And Reprocessing Validation Data For This Device Type Must Be Included In A 510(k) Submission (82 Fr 26807, Available At Https://www.gpo.gov/fdsys/pkg/fr-2017-06-09/pdf/2017-12007.pdf). The Instrument Is Placed In A Tray With Each Lumen End Positioned In Opposite Sides Of The Tray To Allow Enough Detergent And Rinsing Water Pass Through The Lumens Of The Endoscopes..

Submission Details

510(k) Number K203199 FDA.gov
FDA Decision Cleared Substantially Equivalent - Traditional 510(k) (SESE)
Date Received October 29, 2020
Decision Date December 01, 2020
Days to Decision 33 days
Submission Type Special
Review Panel General Hospital (HO)
Summary Summary PDF

Device Classification

Product Code NVE — Washer, Cleaner, Automated, Endoscope
Device Class Class II - Special Controls
CFR Regulation 21 CFR 876.1500
Definition This Automated Device Is Intended To Be Used To Clean Endoscopes. Endoscopes That Are Intended To Be Cleaned By The Automated Cleaner System Should Have Been Pre-cleaned And Tested For Leaks And Lumen Obstructions According To The Instrument Manufacturer's Instructions And Current Professional Practices Prior To Processing In The System. The System Includes A Chemical Dispensing System That Meters Out A Predetermined Volume Of Detergent During The Appropriate Cleaning Cycle. If The Device Is Reusable, Validated Reprocessing Instructions And Reprocessing Validation Data For This Device Type Must Be Included In A 510(k) Submission (82 Fr 26807, Available At Https://www.gpo.gov/fdsys/pkg/fr-2017-06-09/pdf/2017-12007.pdf). The Instrument Is Placed In A Tray With Each Lumen End Positioned In Opposite Sides Of The Tray To Allow Enough Detergent And Rinsing Water Pass Through The Lumens Of The Endoscopes.

Similar Devices — NVE Washer, Cleaner, Automated, Endoscope

All 11
AMSCO 600 Steam Sterilizer, V-PRO maX 2 Low Temperature Sterilization System, V-PRO s2 Low Temperature Sterilization System, V-PRO 60 Low Temperature Sterilization System, RAS 12 Rack, RAS 12 Long Rack, RAS Cycle of the AMSCO 7052HP and 7053HP Single Chamber Washer Disinfector
K222849 · Steris · Sep 2022
AMSCO 600 Steam Sterilizer, V-PRO maX 2 Low Temperature Sterilization System, V-PRO s2 Low Temperature Sterilization System, RAS 12 Rack, RAS 12 Long Rack, RAS Cycle of the AMSCO 7052HP and 7053HP Single Chamber Washer Disinfector
K222543 · Steris · Aug 2022
RAS 12 Rack, RAS 12 Long Rack, RAS Cycle of the AMSCO 7052HP/7053HP Single Chamber Washer/Disinfector
K200577 · STERIS Corporation · Apr 2020
RAS 12 Rack, RAS 12 Long Rack
K190081 · STERIS Corporation · Aug 2019
DA VINCI SONICPRO CLEANING SYSTEM, MODEL 400253
K073112 · Intuitive Surgical, Inc. · Aug 2008
MANZI CLEANER SYSTEM
K043314 · Langford IC Systems, Inc. · Jun 2005